The Compressor, Compressed Air System Why Is It Important?

The compressor air system, the compressed air from the compressor and generated the electricity usage of all it is important for you to take advantage in the most effective way. Screw compressors used in industry nowadays, the majority of the energy that you spend in this respect they can’t turn the compressed air. Existing installations are made when purchased, or the operating pressure of the compressor the compressed air flow rate (the amount of air produced by the liter/min,M3/min, etc.) that will be used in accordance with the size of the business to be made, the length of the installation should be designed. Because the capacity of your compressor and screw fittings are made regardless of the technical issues mentioned above, you purchase the most efficient use of compressed air produced by the compressor causes. Screw compressor compressor wiring required diameter smaller than the capacity of the section is selected, screw air compressor installations with the output consists of the differences between your points later. For example, while your pressure screw compressor 8 bar pressure 6 Bar 7 bar pressure at 30-40 yards to read your installation you can read. The reason for this is inadequate plumbing compressed air connection elbow cap t kesitin you too much of your installation, Manson, etc accessories such as using your installation is very lengthy, although at certain points may be placed in the reserve tank. Ultimately, you notice the fuel cost of the extra electricity back as 2 bars together. Monthly and annual cost translates to a serious loss of these figures in calculations.

How To Design The Right Pressurised Air Can I Do?

Screw compressed air system from the output of your compressor plumbing do not neglect taking at least one or two sizes larger.(for example, the output of a compressor 30 hp screw air compressor of this size usually is 1 inch and 3/4 inch or 1 1/4 inch installation to be applied to a {plastic} 1 inch {metal} must be.)

The capacity of your compressor compressed air is appropriate, because your tank, so make sure it is not small or too large.

To give you just the aesthetic look of it unnecessary and excessive elbow installation, t, link,collar, etc don’t make connections. This causes a loss of pressure when placed unnecessary connections. ( 0.8 bar every 10 meters of appropriate capacity in installations without a pressure loss occurs.)

50 meters after your plumbing, if possible, add extra air reserve tank.

No comment

Leave a Reply

Your email address will not be published. Required fields are marked *